This material is made available to facilitate private study, scholarship, or research. It may be protected by copyright, trademark, privacy, publicity rights, or other interests not owned by UNLV. Users are responsible for determining whether permissions are necessary from rights owners for any intended use and for obtaining all required permissions. Acknowledgement of the UNLV University Libraries is requested. For more information, please see the UNLV Special Collections policies on reproduction and use (https://www.library.unlv.edu/speccol/research_and_services/reproductions) or contact us at special.collections@unlv.edu.

Digital Provenance

Digitized materials: physical originals can be viewed in Special Collections and Archives reading room

Publisher

University of Nevada, Las Vegas. Libraries

Los Angeles* January 13th* 19^9 Hr. Prank Strong: Pursuant to your request and through the courtesy of J.li. Montgomery (k Co* Xne*, the engineering fire that designed end supervised oonstruotion of the Basic Hagneslun* Xno* ester system, 1 «b enoloslng herewith: 3 00pies of the Montgoaery Qo. letter of Beotaber 21* 15M*3„ with estiaatss referred to therein! 3 prints of the nap furnished by you upon whloh we have noted looatlone of the various facilities contemplated* terelnal preasuree and other data* fhe system is designed in accordance with area* quantity and terelnal preeeure requirements euhwitted by you and pipe line looatlone oonfore with those noted upon the sketch aap furnished* Pipe line and pimping facilities are dsslgnsd to provide: S6 M«G*P*0* oapaoity for delivery to a reservoir and treating plant to be located in vicinity of the intersection of present Street and Charleston Boulevard; 10 M.C.P.D* capacity for delivery thence to the LVLdW Company water producing field for distribution through the existing systsw; 10 u.C.P.B* for delivery northerly from the reservoir and treat** ing plant - 6 M.O.P.D* to the Arey Airport with terelnal pressure of 35-lbe* and b M.a.P.O. to Berth Lae Vegas Area with like terelnal pressure; 6 M.eup.s* oapaoity to the southerly area with terelnal pres­sure at the County Alirport of 9§»lbs* Our satinets of cost in the anount of $9,58k*ooo.oo it submitted with the following consent: (1 ) this is a purely preliminary estiaate Bade without field survey* it being understood that an approxlnate cost figure is desired to enable consideration of weans of financing the project* (2) a s you pointed out in furnishing data* the terelnal quantities here used are subject to revision upon accumulation of data as to present and anticipated requirements to the various areas. It would seen that* with conservation of the under­ground supply to i# effected by Btetrlet Control* the quantity requirements may be reduced*