This material is made available to facilitate private study, scholarship, or research. It may be protected by copyright, trademark, privacy, publicity rights, or other interests not owned by UNLV. Users are responsible for determining whether permissions are necessary from rights owners for any intended use and for obtaining all required permissions. Acknowledgement of the UNLV University Libraries is requested. For more information, please see the UNLV Special Collections policies on reproduction and use (https://www.library.unlv.edu/speccol/research_and_services/reproductions) or contact us at special.collections@unlv.edu.

Digital Provenance

Digitized materials: physical originals can be viewed in Special Collections and Archives reading room

Publisher

University of Nevada, Las Vegas. Libraries

% Y ; ' # y : ' ? ? 0 Y 1 a. Approximately 15 LF of 8” cast iron water mains. will l! 2 b. Approximately 4,385 LF of 6” cast iron water mains. 3 c. Approximately 40 LF of 6M cast iron fire hydrant connections. 4 The cost of constructing said water mains (exclusive of cost of con- 5 structing cast iron fire hydrant connections) is agreed to he the 6 sum of fl14,679,00, 7 2, Said water mains shall he constructed of 6” and 8” Class 8 150 B & S cast iron pipe and shall he in accordance with Federal 9 specifications WWP 421 Type 1, All joints shall he cement. All 10 fittings shall he new, all hell cast iron equal to ASA Standard 11 Class 250. All valves shall he double disk, parallel seat bronze 12 mountings conforming to AWWA standards, not less than 175 lbs,, and 13 all valve boxes shall he of cast iron of appropriate size for each 14 valve. Unless otherwise approved by a duly authorized representa- 15 tive of the Company, all pipe valves and fittings shall he manu- 16 factured by the Pacific States Cast Iron Pipe Company or Mueller 17 Company. All pipe lines shall he chlorinated in accordance with 18 AWWA specifications, shall he subject to the approval and acceptance 19 of State and City Health Authorities, and shall he constructed at 20 an elevation to he designated by a duly authorized representative 21 of the Company, hut in no event shall there he less than 36tt of 22 covering over such water mains. All workmanship, material and id- 23 stallation of said water mains shall he subject to the approval and 24 acceptance of a duly authorized representative of the Company, 2 5 3. At Subdivider’s sole cost and expense to survey and 26 accurately stake upon the ground the line along which said water -2- ? H M