    This material is made available to facilitate private study, scholarship, or research. It may be protected by copyright, trademark, privacy, publicity rights, or other interests not owned by UNLV. Users are responsible for determining whether permissions are necessary from rights owners for any intended use and for obtaining all required permissions. Acknowledgement of the UNLV University Libraries is requested. For more information, please see the UNLV Special Collections policies on reproduction and use (https://www.library.unlv.edu/speccol/research_and_services/reproductions) or contact us at special.collections@unlv.edu.

    Digital Provenance

    Digitized materials: physical originals can be viewed in Special Collections and Archives reading room

    Publisher

    University of Nevada, Las Vegas. Libraries

    LAS VEGAS, NEVADA Friday, November 10, 1950 PUMPING TEST - WELL NO. 10 — 15-5/811 O.D. Casing \ - o f : Well Pressure - 9-3/4 lbs. Free flow prior to pumping test - 1316 GPM Layne and Bowler Turbine Pump - 3 bowls 401 below top of cross Started Pump 3:15 P.M. Flow GPM Draw Down Concrete Mat Below C/L of Cross 3:40 ii 2117 16.3* 18' 3:56 it 2117 16.3' 18' 4:41 H 2085 15.8* 1 7 f 3lt' 31f' Increase RPM 4:46 8 2471 29.8' 4:54 8 2471 29.8' 5:04 8 2471 29.8« 31#' This well has produced crystal clear water through­out all the series of tests and will be good for approximately 2500 GPM with turbine pump with draw down of 31^' with pumps operating on Wells No. 9 and No. 11.