    This material is made available to facilitate private study, scholarship, or research. It may be protected by copyright, trademark, privacy, publicity rights, or other interests not owned by UNLV. Users are responsible for determining whether permissions are necessary from rights owners for any intended use and for obtaining all required permissions. Acknowledgement of the UNLV University Libraries is requested. For more information, please see the UNLV Special Collections policies on reproduction and use (https://www.library.unlv.edu/speccol/research_and_services/reproductions) or contact us at special.collections@unlv.edu.

    Digital Provenance

    Digitized materials: physical originals can be viewed in Special Collections and Archives reading room

    Publisher

    University of Nevada, Las Vegas. Libraries

    1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 (e) Approximately 150 LF of 6" cast iron fire hydrant connection, in location as shown in yellow on the map hereto attached and by reference made a part hereof* The cost of constructing said water mains (exclusive of cost of constructing the said 150 LF of 6M cast iron fire hydrant connections) is the agreed sum of FIFTY THREE THOUSAND & NO/lOO ($53,000.00) DOLLARS, the expense of which shall be borne by the Owner* 2. Said water mains shall be constructed of 12”, 10", 8" and 6” cast iron pipe and shall be in accordance with AWWA specifications. All joints shall be cement and all pipe shall be new B & S cast iron, equal to AWWA Class 150, All fittings shall be new, all bell cast iron equal to AWWA Class 150, and all valve boxes shall be of cast iron of appropriate size for each valve. Unless otherwise approved by a duly authorized representative of the Company, all pipes, valves and fittings shall be manufact­ured by Pacific States Cast Iron Pipe Company or Mueller Company. All pipe lines shall be chlorinated in accordance with AWWA speci­fications, shall be subject to the approval and acceptance of State and City Health Authorities, and shall be constructed at an elevation to be designated by a duly authorized representative of the Company, but in no event shall there be less than 36» of cover­ing over such water mains. All workmanship, material and the in­stallation of said water mains shall be subject to the approval and acceptance by a duly authorized representative of the Company. 3. At Owner’s sole cost and expense to survey and ac- - 2 - X-//5