Skip to main content

Search the Special Collections and Archives Portal

man000164 30

Image

File
Download man000164-030.tif (image/tiff; 37.76 MB)

Information

Digital ID

man000164-030
    Details

    Rights

    This material is made available to facilitate private study, scholarship, or research. It may be protected by copyright, trademark, privacy, publicity rights, or other interests not owned by UNLV. Users are responsible for determining whether permissions are necessary from rights owners for any intended use and for obtaining all required permissions. Acknowledgement of the UNLV University Libraries is requested. For more information, please see the UNLV Special Collections policies on reproduction and use (https://www.library.unlv.edu/speccol/research_and_services/reproductions) or contact us at special.collections@unlv.edu.

    Digital Provenance

    Digitized materials: physical originals can be viewed in Special Collections and Archives reading room

    Publisher

    University of Nevada, Las Vegas. Libraries

    (a) Approximately 2830 lineal feet of 8* and 6850 lineal feet of 6 " cast iron water mains* (b) Approximately 100 lineal feet of 6 * cast iron fire hydrant connections# The cost of constructing said water mains (exclusive of the cost of constructing the said 100 lineal feet of cast iron fire hydrant connections) is agreed to he the sum of f34,640*00* 2# Said water mains shall he constructed of 8* and 6 " cast iron pipe and shall he in accordance with AWWA specifications. All joints shall he cement and all pipe shall he new B & S cast iron, equal to AWWA Class 150* All fittings shall he new, all hell cast iron equal to AWWA Class 150, and all valve boxes shall he of cast iron of appropriate size for each valve. Unless otherwise approved by a duly authorized representative of the Company, all pipes, valves and fittings shall he manufactured by Pacific States Cast Iron Pipe Company or Mueller Company* All pipe lines shall he chlorinated in accordance with AWWA specifications, shall he subject to the approval and acceptance of State and city health authorities, arui shall he constructed at an elevation to he designated by a duly authorized representative of the Company, hut in no event shall there he less than 36" of covering over such water mains* All workmanship, material and the installation of said water mains shall he subject to the approval and acceptance by a duly authorized representative of the Company* 3. At Subdivideds sole cost and expense to survey and accurately stake upon thi ground the line along which said water nalns are to he laid, and to indicate street and alley grades by appropriate stakes* - 2-