Skip to main content

Search the Special Collections and Archives Portal

upr000269 23

Image

File
Download upr000269-023.tif (image/tiff; 26.72 MB)

Information

Digital ID

upr000269-023
Details

Rights

This material is made available to facilitate private study, scholarship, or research. It may be protected by copyright, trademark, privacy, publicity rights, or other interests not owned by UNLV. Users are responsible for determining whether permissions are necessary from rights owners for any intended use and for obtaining all required permissions. Acknowledgement of the UNLV University Libraries is requested. For more information, please see the UNLV Special Collections policies on reproduction and use (https://www.library.unlv.edu/speccol/research_and_services/reproductions) or contact us at special.collections@unlv.edu.

Digital Provenance

Digitized materials: physical originals can be viewed in Special Collections and Archives reading room

Publisher

University of Nevada, Las Vegas. Libraries

• 2 * WO 5406* Retired tr a c t o f land containing an area o f 507 acres and improvements thereon con sistin g o f water supply f a c i l i t i e s at Las Vegas account sold to Las Vegas Land and Water Co* R&E $330,599.66 (Cr) WO S-3441: Constructed booster pumping sta tio n a t Charleston Blvd. R eservoir, Las Vegas, con sistin g o f tank, pipe lin e s , pimp­ing equipment, power and other necessary appurtenances as follow s* Erected 300,000 gallon capacity s te e l water tank on 100 f t . tower by Chicago Bridge and Iron Co. in accordance with Con­tr a c t NLD 2594 dated September 25, 1952. Constructed concrete foundations fo r tank tower involving 203 cu. yds. o f excavation in so lid rode and 51 cu. yds. in natural ground which was perfonaed by Morrison—Knudsen Co. Contract NLD 2536 and 2672. Constructed 2473 f t . o f 14” water lin e and 60 f t , o f 10” water lin e to connect with e x istin g Las Vegas Land & Water Co. lin e involving 1440.7 cu. yds. of excavation also nec­essary overflow valves and piping. Construct 2522.5 f t . of addition al power destribution lin e s involving 46 cu, yds. o f excavation fo r poles and in s t a ll th rse transform ers 75 KVA 2400 to 430 x 240 v o lts with 2 1/2% ta p s. In sta lle d two Wentroath pumps Nos. 7053 and 7059, v e r tic a l turbine type, encased booster pumps, type SKA 2-12, 3 -stage 14-900 pimp with 2-100 HPQE e le c tr ic motors Nos. 6949033 and 6949490 model 5K6533VA8A, 440 v o lt s , 60 cycle, 3 phase, 1300 RFM, normal torque low sta rtin g current, pump encased in 20" O.S. S te e l case, 3* center o f in le t to face o f case flan ge suction in le t 12” s t a , p lain ends, 2 angle brackets needed on side o f case at bottom with b o lt holes 26” 00, a l l per Wentroath DWG XR-279. In sta lle d necessary panel control boards, s ta r te r s , c irc u it breakers, re la y s, etc.