Copyright & Fair-use Agreement
UNLV Special Collections provides copies of materials to facilitate private study, scholarship, or research. Material not in the public domain may be used according to fair use of copyrighted materials as defined by copyright law. Please cite us.
Please note that UNLV may not own the copyright to these materials and cannot provide permission to publish or distribute materials when UNLV is not the copyright holder. The user is solely responsible for determining the copyright status of materials and obtaining permission to use material from the copyright holder and for determining whether any permissions relating to any other rights are necessary for the intended use, and for obtaining all required permissions beyond that allowed by fair use.
Read more about our reproduction and use policy.
I agree.Information
Digital ID
Permalink
Details
More Info
Rights
Digital Provenance
Publisher
Transcription
MAIL ADDRESS 5075 Santa Fe Avenue D O B O V o m o T • I A LO S r . U . d C JX 2078— terminal Annex AN G ELES , C A LIFO RN IA LOS ANGELES 54, CALIFORNIA AttgUSt 29, X944 Union P a cific Railroad Company 2025 Hunter Street Los Angeles, C aliforn ia Subject* lou r Order #36-80-772 Attention* Mr. J . P. Mack Las Vegas Fire Fuap Our Order A A 802______ Gentleness We re fe r to the Worthington fir e pump supplied fo r the above order. In accordance with our agreement with Mr. R* L. Adamson, we are supplying a nee shaft together with a new set o f bearings* fe have inspected the broken sh a ft, which is broken newt to the bearing on the coupling end. I t is im possible to d e fin ite ly determine the cause o f the breakage} however, th is is the id en tica l spot where breakages take place from misalignment. We are attaching in struction bu lletin W-300-E1C which goes in to considerable d e ta il concerning the fie ld alignments* A motor and pump can be mounted properly at the shop and in the fie ld , but s t i l l be out o f lin e a fter the unit has been placed on the foundation. Misalignment nay be due both to d istortion o f the bedplate when placing on the foundation, and by rig id ly connecting the discharge nosales o f the pump to the piping* In our agreement with Mr* Adamson we requested that the pump and motor remain unchanged. We further requested that the new rotatin g element be placed in the pump and then check the coupling fo r alignment. I f the coupling halves are found to be in good alignment, we w in supply these parts a t no charge. On the other hand, i f misalignment is evident, you w ill be charged fo r these parts. The most important thing to now consider is to make certain that the pump and motor shafts are in proper alignment so that there w ill not be further breakage o f this type. As we do not have the easing in our warehouse i t is im possible to properly adju st the loca tion o f the im peller on the sh a ft. A fter the rotating element has been in sta lled in the pump i t w ill be necessary fo r the im peller to be centralised within the casing by means o f the shaft sleeve nuts. le have advised your Mr. Adamson that the rotatin g element is now ready fo r your pickup. ifiS flt. fa? f Uyr * ,