    This material is made available to facilitate private study, scholarship, or research. It may be protected by copyright, trademark, privacy, publicity rights, or other interests not owned by UNLV. Users are responsible for determining whether permissions are necessary from rights owners for any intended use and for obtaining all required permissions. Acknowledgement of the UNLV University Libraries is requested. For more information, please see the UNLV Special Collections policies on reproduction and use (https://www.library.unlv.edu/speccol/research_and_services/reproductions) or contact us at special.collections@unlv.edu.

    Digital Provenance

    Digitized materials: physical originals can be viewed in Special Collections and Archives reading room

    Publisher

    University of Nevada, Las Vegas. Libraries

    a* Approximately 1,270 LF of 8“ cast iron water mains. t>. Approximately 3,155 LF of 6” cast iron water mains. c* Approximately 120 LF of 6M cast iron fire hydrant connections* The cost of constructing said water mains (exclusive of cost of constructing approximately 120 LF of 6” cast iron fire hydrant connections) is agreed to be the sum of $16,213*00. 2, Said water mains shall be constructed of 8“ and 6n Class 150 Bell and Spigot cast iron pipe which shall conform with Federal specifications WWP 421 Type 1. All joints shall be cement. All fittings shall be new all bell cast iron equal to ASA Standard Class 250. All valves shall be double disk, parallel seat, bronze mountings conforming to AWWA standards, not less than 175 lbs., and all valve boxes shall be of cast iron of appropriate size for each valve. Unless otherwise approved by a duly authorized representa­tive of the Company, all pipe, valvee and fittings shall be manu­factured by the Pacific States Cast Iron Pipe Company or Mueller Company. All pipe lines shall be chlorinated in accordance with AWWA specifications, shall be subject to acceptance and approval of the State and City Health Authorities, and shall be constructed at an elevation to be designated by duly authorized representative of the Company, but in no event shall there be less than 36” of cover over said water mains. All workmanship, material and installation of said water mains shall be subject to the approval and acceptance of a duly authorized representative of the Water Company. 3. At Subdivider’s sole cost and expense to survey and accurately stake upon the ground the line along which said water -2-