    This material is made available to facilitate private study, scholarship, or research. It may be protected by copyright, trademark, privacy, publicity rights, or other interests not owned by UNLV. Users are responsible for determining whether permissions are necessary from rights owners for any intended use and for obtaining all required permissions. Acknowledgement of the UNLV University Libraries is requested. For more information, please see the UNLV Special Collections policies on reproduction and use (https://www.library.unlv.edu/speccol/research_and_services/reproductions) or contact us at special.collections@unlv.edu.

    Digital Provenance

    Digitized materials: physical originals can be viewed in Special Collections and Archives reading room

    Publisher

    University of Nevada, Las Vegas. Libraries

    u 1 1B [^M^B $ w iAW ® ?" • S i a* Approximately 505 LF of 6M cast iron water mains. 2 b. Approximately 562 LF of 4" cast p.r*on water mains. 3 c. Approximately 10 LF of 6” fire hydrant connections. 4 The cost of constructing said water mains (exclusive of the cost of 5 constructing fire hydrant connections) is agreed to be the sum of 6 $2,842.00. 7 2, Said water mains shall be constructed of 6" and 4” Class 8 150 B & S cast iron pipe and shall be in accordance with Federal 9 specifications WWP 421 Type 1. All joints shall be cement. All 10 fittings shall be new, all bell cast iron equal to ASA Standard 11 Class 250. All valves shall be double disk, parallel seat bronze 12 mountings conforming to AWWA standards, not less than 175 lbs., 13 and all valve boxes shall be of cast iron of appropriate size for 14 each valve. Unless otherwise approved by a duly authorized repre- 15 sentative of the Company, all pipe valves and fittings shall be 16 manufactured by the Pacific States Cast Iron Pipe Company or Mueller 17 Company. All pipe lines shall be chlorinated in accordance with 18 AWWA specifications, shall be subject to the approval and acceptance 19 of State and City Health Authorities, and shall be constructed at 20 an elevation to be designated by a duly authorized representative 21 of the Company, but in no event shall there be less than 36" of 22 covering over such water mains. All workmanship, material and 23 installation of said water mains shall be subject to the approval 24 and acceptance of a duly authorized representative of the Company. 25 3. At Subdivider’s sole cost and expense to survey and 26 accurately stake upon the ground the line along which said water l' I -2- PI'111