    This material is made available to facilitate private study, scholarship, or research. It may be protected by copyright, trademark, privacy, publicity rights, or other interests not owned by UNLV. Users are responsible for determining whether permissions are necessary from rights owners for any intended use and for obtaining all required permissions. Acknowledgement of the UNLV University Libraries is requested. For more information, please see the UNLV Special Collections policies on reproduction and use (https://www.library.unlv.edu/speccol/research_and_services/reproductions) or contact us at special.collections@unlv.edu.

    Digital Provenance

    Digitized materials: physical originals can be viewed in Special Collections and Archives reading room

    Publisher

    University of Nevada, Las Vegas. Libraries

    1 2 3 4 5 6 7 the following: (a) Approximately 1,614 LB of 6” cast iron water mains, (b) Approximately 26 LF of 6" cast iron fire hydrant connections# The cost of constructing said water mains (exclusive of cost of constructing the said 26 LF cast iron fire hydrant connections) is agreed to he the sum of $>5,346*00, 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 2# Said water mains shall he constructed of 6M Class 150 B & S cast iron pipe and shall he in accordance with Federal specifications WWP 421 Type 1. All joints shall he cement; all fittings shall he new, all hell cast iron equal to ASA Standard Class 250# All valves shall he double disk, parallel seat bronze mountings conforming to AWWA standards, not less than 17jJ lbs#, and all valve boxes shall be of cast iron of appropriate size for each valve# Unless otherwise approved by a duly authorized repre­sentative of the Company, all pipe valves and fittings shall be manufactured by the Pacific States Cast iron Pipe Company or Mueller Company. All pipe lines shall be chlorinated in accordance with AWWA specifications, shall be subject to the approval and acceptance of State and City Health Authorities, and shall be constructed at an elevation to be designated by a duly authorized representative of the Company, but in no event shall there be less than 36n of covering over such Water mains. All workmanship, material and installation of said water mains shall be subject to the approval and acceptance by a duly authorized representative of the Company#