Please note that UNLV may not own the copyright to these materials and cannot provide permission to publish or distribute materials when UNLV is not the copyright holder. The user is solely responsible for determining the copyright status of materials and obtaining permission to use material from the copyright holder and for determining whether any permissions relating to any other rights are necessary for the intended use, and for obtaining all required permissions beyond that allowed by fair use.
Read more about our reproduction and use policy.
I agree.Information
Digital ID
Permalink
Details
Member of
More Info
Rights
Digital Provenance
Publisher
Transcription
V Cleaned out to 115? with 6- 1 /8" Hughes b it . Ko oetaent below 1 H 2 . 6/ 4/42 Made production te st o f zone from 1100 to 1150 as fo llo w s: Ran in H allib u rto n formation teeter with 18.97* long perforated t a i l piece (in c lu d in g bomb on bottom) on bottom o f 4t* d r i l l pipe. Set packer o f te ste r at 1036. Ko water cushion in d r i l l pipe above te ste r. Opened valve in te ste r at 2*09 A * . H u ifi reached top o f d r i l l pipe at 4 * 1 1 A M . (2 h rs. and 2 min.) At 10:00 P.H . w ell was flow in g 20 g a ls , o f muddy water per minute through 7/8" opening in te ste r. Closed in pressure at top o f d r i l l pipe 3 1 5 # per sq. inch (on white faced gauge the one that re g iste re d 2 1 # on top zone) and 16## per sq. inch on green faced gauge, (th e one that showed 23# on top zone). At 12*30 A .M ., dune $th the w e ll continued to flow g a ls , o f water per min. Closed in pressure had increased to 16-3/4# per sq. inch on white faced gauge and 18 lb e . per sq. in . on green faced gauge. At 12s40 A M ., dune 5th, closed tool and p u lled packer loose, f l u i d in d r i l l pipe at time o f clo sin g valve was c le a r water. P u lle d out te ste r and took two one ga llo n samples o f the water fo r a n a ly sis. One sample was 88* above te ste r and other sample was 44 f t . above te ste r. MOTE* During the te st, top o f d r i l l pipe where pressure gauges were located was 3# fe e t above ro tary ta b le . When the closed in pressure on the zone 820 - 950 was taken, the top o f the casing and gauges were located in the c e lla r 7 f t . below th is depth. Reducing the column o f flu i d , mathematically, to the same elevation as that at which the upper zone readings were taken, the re la t io n between the closed in pressure o f the two zones i s as follow s* Gauge Used Whits faced gauge Green faced gauge Zone p B i l l 2 1 lb s . 23 lb s . Zone 1100-1150 19-3/4 lb s . 2 1 lb s . W ell then stood id le u n t il June 6th. At 12*00 noon on that day w e ll started flow in g mud f lu id . Ran d r i l l pipe to 800, pumped water in hole and allowed w ell to flow . On a w eir te st taken at 4: 00 A M ., **une 6th, well flowed 1" o f water through a 24" w eir. Water a t.th e time contained considerable red s i l t and ro tary mud. MOTH: A ll measurements, including casing ©re taken from the top o f the ro tary ta b le . Top o f rotary ta b le i s 5 . 5 * above cement matt. 6/ 7/42 Took closed in pressure at cement matt le v e l. Gauge showed 24# per sq. inch (green faced gauge). 6/ 3/42 Washed p erforation s in 7* lin e r from 1157 up to top o f lin e r with M eGaffy-Taylor p erfo ratio n washer.