Please note that UNLV may not own the copyright to these materials and cannot provide permission to publish or distribute materials when UNLV is not the copyright holder. The user is solely responsible for determining the copyright status of materials and obtaining permission to use material from the copyright holder and for determining whether any permissions relating to any other rights are necessary for the intended use, and for obtaining all required permissions beyond that allowed by fair use.
Read more about our reproduction and use policy.
I agree.Information
Digital ID
Permalink
Details
Member of
More Info
Rights
Digital Provenance
Publisher
Transcription
V U-l-h JAN. 22, 1844 [As Amended] Corrected Copy WAR PRODUCTION BOARD (Corrected Copy) c Part 4500—Power, Water, Gas, and Central Steam Heating [Supplementary Utilities Order U-l-h, as Amended Jan. 22, 1944] § 4500.9 Supplementary Utilities Order U-l-h—(a) Permission to build certain extensions. In accordance with the provisions of paragraph (j) of Utilities Order U-l, extensions of electric, gas, water, and central steam heat facilities may be made or connected by a producer, subject to the restrictions of paragraph (b) below, to serve the following types of consumer premises: (1) Premises which are being built or remodeled under authority of a specific authorization issued pursuant to Conservation Order L-41, (2) Premises which will be occupied exclusively by the Army, Navy, Maritime Commission, War Shipping Administration or Civil Aeronautics Authority, (3) Premises of an industrial or commercial consumer, (i) In cases where the extension or enlargement of utilities facilities is necessary for the production of one of the products or the supply of one at the services listed in Schedules I and IS of CMP Regulation 5 or (M) In cases where the eommmaet is an electric, water, gas, steam heat, telephone, or telegraph utility; or is engaged hi the petroleum industry, exeept in re- tdl marketing, as theec terms are defined ia Preference Rating Order P-8B-b; or is engaged in the business of mining, or of burning refractories, and has been as- signed a serial number under Preference Bating Order P-56; or is engaged in the business of radio communication or radio broadcasting; or is a school, church, or hospital. (b) Restrictions on construction. Extensions of the type permitted by paragraph (a) of this order may be built only if all of the following conditions are satisfied : (1) The total cost of material for any such extension, exclusive of any part built by or for the consumer, exceeds $1,500 but does not exceed $5,000. No job or project may be subdivided to come within these limits. 2 * 5 (2) The extension does not duplicate an adequate service already installed "or constitute a stand-by service. / (3) No other producer can render the 'same service with lesser amounts of critical material. s-'(4) In the case of extensions to buildings which are to be used exclusively for dwelling purposes the extension (including service drop or service pipe, and any portion built by or for the consumer) can be built within the limits established by the Housing Utilities Standards issued by the War Production Board. (5) In the case of extensions to premises which are to be built or remodeled under authority of a specific authorization applied for pursuant to Conservation Order L-41, the producer has completed Form WFB-3348, and delivered it to the builder for attachment to tee builder’s application for L-41 approval. (c) Assignment of preference rating and CMP allotment number. (1) Hie preference rating AA-3 is hereby assigned to orders for material other than controlled material, and the abbreviated CMP allotment number P-2 is hereby assigned to orders for controlled material, to be placed by a producer for use in the construction of extensions of facilities authorized by this supplementary order or to replace in inventory material so used. (2) The preference rating and allotment number assigned above may be applied by a producer by using the certification provided in CMP Regulation 7. (3) An order for controlled material bearing the CMP allotment number U-2 shall be deemed an authorized controlled materials order. This allotment number shall constitute an “allotment number or symbol” for the purpose of CMP Regulation 3. (d) Acquisition of material. The acquisition of material for extensions of facilities authorized by this supplementary order is subject to the following restrictions: (1) It may be ordered only to the extent that it is not available in the producer’s inventory in excess of a practical working minimum. (2) If taken from such excess inventory it may not be replaced. (3) If taken from practical working minimum inventory it may be replaced therein only in accordance with paragraph (b) of Utilities Order P-1. (4) It may not be ordered until either (i) The producer has been advised that the builder of the structure to be served has received L-41 approval, or (ii) The producer has been advised bjr such builder that L-41 approval is oat required and has received a written request from such builder to supply tee utility service. ' (e) Other orders. This order does not constitute a release, in the case of gas producers or consumers, from the restrictions of Utilities Order U-7 or Limitation Order L-174. Issued this 22d day of January 1944. War Production Board, By J. Joseph Whelan, Recording Secretary. O— Mfn Board 9484— p. 1