Copyright & Fair-use Agreement
UNLV Special Collections provides copies of materials to facilitate private study, scholarship, or research. Material not in the public domain may be used according to fair use of copyrighted materials as defined by copyright law. Please cite us.
Please note that UNLV may not own the copyright to these materials and cannot provide permission to publish or distribute materials when UNLV is not the copyright holder. The user is solely responsible for determining the copyright status of materials and obtaining permission to use material from the copyright holder and for determining whether any permissions relating to any other rights are necessary for the intended use, and for obtaining all required permissions beyond that allowed by fair use.
Read more about our reproduction and use policy.
I agree.Information
Digital ID
Permalink
Details
Member of
More Info
Rights
Digital Provenance
Publisher
Transcription
Las Vegas - April 12, 1954 W 2 >1-149 Mr. C* M. Gory - Las Vegas cos Mr, Wia. Reinhardt Mr. S. E# Bennett Will you please prepare the usual for® of Refund Agreement with Stewart Ogden Apts., Inc., a Nevada corporation whose address la 120 Cleveland Street, Las Vegas, Nevada, covering construction of oast iron water mains to serve Slock 6 of Noblitt Addition, Las Vegas, Nevada. Location of proposed water mains will he as indicated on agreement prints which I will furnish you after they have been prepared by Mr. R. L. Adamson. ,Uj SUBDIVIDE!* AGREES: 1. At its own expense to furnish all necessary labor and materials and to construct: (a) Approximately ?8o LF of 6* east iron water mains. The cost of constructing s&id water mains is the agreed sura of #2,783.00. 2. Said water mains shall be constructed of 6 * Glass 150 B & S oast iron pipe and shall be in accordance with Federal specifications WWP 421 Type 1. All Joints shall be cement. All fittings shall be new, all bell cast iron equal to ASA Standard Class 250. All valves shall be double disk, parallel seat bronze mountings conforming to AWWA standards, not less than 175 lbs., and all valve boxes shall be of east iron of appropriate size for each valve. Unless otherwise approved by a duly authorized representative of the Company, all pipe valves and fittings shall be manufactured by the Pacific States Cast Iron Pip© Company or Mueller Company. All pipe lines shall be chlorinated in accordance with AWWA specifications, shall be subject to the approval and acceptance of State and City Health Authorities, and shall be constructed at an elevation to be designated by a duly authorized representative of the Company, but in no event shall there be less than 36* of covering over such water mains. All workmanship, material and installation of said water mains shall be subject to the approval and acceptance by a duly authorized representative of the Company. • To 3 stake water lines.