Copyright & Fair-use Agreement
UNLV Special Collections provides copies of materials to facilitate private study, scholarship, or research. Material not in the public domain may be used according to fair use of copyrighted materials as defined by copyright law. Please cite us.
Please note that UNLV may not own the copyright to these materials and cannot provide permission to publish or distribute materials when UNLV is not the copyright holder. The user is solely responsible for determining the copyright status of materials and obtaining permission to use material from the copyright holder and for determining whether any permissions relating to any other rights are necessary for the intended use, and for obtaining all required permissions beyond that allowed by fair use.
Read more about our reproduction and use policy.
I agree.Information
Digital ID
Permalink
Details
More Info
Rights
Digital Provenance
Publisher
Transcription
w . i. K. NOV 281966 am I X l Los Angeles - November 25# 1966 WO-40415 Nr. JU M. Brown - Omaha (ce * Nr* 6* A. Nr* F* 0* Nr* C* K. Nr. E* C. Cunningham * Salt Lake Schunaan - Salt Lake Cory * Las Vegas Ranwiok - Los Angeles With reference to Work Order 40415 covering construction of asphaltic concrete streets with crushed rock base curb and gutters* water lines* sewer lines complete with manholes* etc. to serve Highland Drive Industrial Diarist at Las Vegas* Nevada* with particular reference to relocation of our existing Well No. 2 which is now located K in the middle of the new proposed Union pacific Street to a new location outside the industrial area. v. 1 am forwarding to you herewith two copies* and to the other gentlemen receiving copy of this letter one copy each# of Invitation to Bid, Fora of Contract Bond* General Conditions and Specifications and Bid Proposal Form which it is proposed to use for securing bids for the drilling of the new well. Particualr attention is invited to fact that Specifications and Bid proposal are based on the drilling of the well by the rotary drilling method* also* that 30-inch diameter conductor pipe or surface protective casing specified! however* it is felt you may wish to leave the type of drilling open cm the specifications and accept either the rotary or cable tool method. Also* you may wish to reduce the else of the conductor or surface protective casing from 30-inch to smaller diameter* possibly as small as 20-inch which is sometimes used with this else well. Will you please review the attached Speciflcati one * Invitation to Bid and Bid Proposal and favor us with any comments or corrections which you feel would result in our obtaining the best possible well at the most economical figure*