Please note that UNLV may not own the copyright to these materials and cannot provide permission to publish or distribute materials when UNLV is not the copyright holder. The user is solely responsible for determining the copyright status of materials and obtaining permission to use material from the copyright holder and for determining whether any permissions relating to any other rights are necessary for the intended use, and for obtaining all required permissions beyond that allowed by fair use.
Read more about our reproduction and use policy.
I agree.Information
Digital ID
Permalink
Details
More Info
Rights
Digital Provenance
Publisher
Transcription
3 - Install a new receiving basin and a new booster pumping station near the Manganese Ores plant for final delivery of water to the terminal reservoirs at Henderson. The pumps and motors now installed at the intake, with columns and one bowl removed, precisely fit the conditions at the proposed new booster pumping plant. The proposed receiving basin would be so constructed that it would supply gravity water to the Las Vegas area and to the booster pump suction header. However, the connections would be such that priority in rights would always be available to the Henderson Industries. Also, the piping and valves would be so arranged that the receiving basin could be by-passed and delivery made directly to Henderson exactly as is now being done. This method of operation would no doubt be used throughout the cool season when Las Vegas water consumption is low. The estimated cost of the reservoir and booster station is $218,100. 4 - Construct a new 48* gravity pipe line from the reservoir in the vicinity of the Manganese Ores plant for delivery of water to the Las Vegas area. The pipe line would also be used to deliver water back from the Las Vegas area to the Henderson industries in emergencies. The estimated cost of the new pipe line is $1,864,900. 5 - Provide 30 million gallons of additional storage capacity. It is suggested that this additional capacity be located in the Las Vegas area at an elevation which would make it available by gravity either to Las Vegas or to the industries at Henderson. However, this additional storage could be located near Manganese Ores or at Henderson and still be of value to all Interested parties. The estimated cost of the new storage facilities is $840,000. 6 - Install additional transformer capacity at Henderson and at the existing booster station; install new transformers, swlteh gear and appurtenances at the proposed new booster station; and, install a new underground cable from ttie existing booster station transformer bank to the intake. Mo change would be necessary in the starting and control equipment at intake Other than to replace the existing current transformers. The estimated cost of all electrical work is $377,700. The estimated cost of the entire project, as outlined herein and as described more fully in the accompanying bound *IMTERIM REPORT8, is $3,475,000. This estimate is subject to revision before presentation of the final report but, unless unforeseen contingencies develop, it will not change materially. When complete, the plant would be first class in every way and, even if it were bdL ng designed new for its Intended use, it is doubtful if it would differ materially from the plan recommended. Respectfully submitted, s/Ralph W. 0‘Neill s/James M. Montgomery