Skip to main content

Search the Special Collections and Archives Portal

upr000187 64

Image

File
Download upr000187-064.tif (image/tiff; 26.55 MB)

Information

Digital ID

upr000187-064
    Details

    Rights

    This material is made available to facilitate private study, scholarship, or research. It may be protected by copyright, trademark, privacy, publicity rights, or other interests not owned by UNLV. Users are responsible for determining whether permissions are necessary from rights owners for any intended use and for obtaining all required permissions. Acknowledgement of the UNLV University Libraries is requested. For more information, please see the UNLV Special Collections policies on reproduction and use (https://www.library.unlv.edu/speccol/research_and_services/reproductions) or contact us at special.collections@unlv.edu.

    Digital Provenance

    Digitized materials: physical originals can be viewed in Special Collections and Archives reading room

    Publisher

    University of Nevada, Las Vegas. Libraries

    < 2 ) with that of the well pump, together with Wallace & Tleman Hellige Com­parator, Falrbanks-Morse portable scale for weighing chlorine, and Westco pump with 1/5 HP motor to deliver water Into mixing chamber - all to be Instal­led in the existing spring house - - - $ l 800 Construct floor with asphaltic covering inside spring house (to comply with re­quirement of State Health authorities) 200 Construct 10' diameter by 1 2 * In height redwood tank with roof covering as re­tention tank to permit 20-minute action of ehlorlne before water is discharged into collecting system to reservoir - 700 Piping and electric connections, trans­former, e t c . ---- ----------------- - 1 200 $ 3 900 2. Install booster pump connected with 2* fire protection line to be constructed within fence enclosure and around res­ervoir, with six risers and three 60' hose reels equipped with nozzles for fire protection ---- ---------------- 2 700 3. To augment water supply if demand occurs, drill one new well about 500 1 in depth to the upper producing horizon, and Install Byron Jackson type of submers­ible pump with pipe line connection - estimated to produce 900,000 GPD - - - $15 500 Brill one new well about 8001 in depth to the lower producing horizon, with pipe line connections, allowing water from same to flow by gravity into the reservoir - estimated to produce 650,000 G P D ------------------------- 12 500 Pipe lines and connections to settling b a s i n ---------------------------- - - 24 600 52 600 4. Install booster pumping facilities, con­sisting of two pumps, which will in­crease the pressure upon the distribut­ing system at delivery points on Main Street by 10 lbs, to 20 lbs, as may be needed - - - - - - - - - - - - - - - - g sqq TOTAL RAILROAD EXPENSE ------------------ |65700