Copyright & Fair-use Agreement
UNLV Special Collections provides copies of materials to facilitate private study, scholarship, or research. Material not in the public domain may be used according to fair use of copyrighted materials as defined by copyright law. Please cite us.
Please note that UNLV may not own the copyright to these materials and cannot provide permission to publish or distribute materials when UNLV is not the copyright holder. The user is solely responsible for determining the copyright status of materials and obtaining permission to use material from the copyright holder and for determining whether any permissions relating to any other rights are necessary for the intended use, and for obtaining all required permissions beyond that allowed by fair use.
Read more about our reproduction and use policy.
I agree.Information
Digital ID
Permalink
Details
More Info
Rights
Digital Provenance
Publisher
Transcription
< 2 ) with that of the well pump, together with Wallace & Tleman Hellige Comparator, Falrbanks-Morse portable scale for weighing chlorine, and Westco pump with 1/5 HP motor to deliver water Into mixing chamber - all to be Installed in the existing spring house - - - $ l 800 Construct floor with asphaltic covering inside spring house (to comply with requirement of State Health authorities) 200 Construct 10' diameter by 1 2 * In height redwood tank with roof covering as retention tank to permit 20-minute action of ehlorlne before water is discharged into collecting system to reservoir - 700 Piping and electric connections, transformer, e t c . ---- ----------------- - 1 200 $ 3 900 2. Install booster pump connected with 2* fire protection line to be constructed within fence enclosure and around reservoir, with six risers and three 60' hose reels equipped with nozzles for fire protection ---- ---------------- 2 700 3. To augment water supply if demand occurs, drill one new well about 500 1 in depth to the upper producing horizon, and Install Byron Jackson type of submersible pump with pipe line connection - estimated to produce 900,000 GPD - - - $15 500 Brill one new well about 8001 in depth to the lower producing horizon, with pipe line connections, allowing water from same to flow by gravity into the reservoir - estimated to produce 650,000 G P D ------------------------- 12 500 Pipe lines and connections to settling b a s i n ---------------------------- - - 24 600 52 600 4. Install booster pumping facilities, consisting of two pumps, which will increase the pressure upon the distributing system at delivery points on Main Street by 10 lbs, to 20 lbs, as may be needed - - - - - - - - - - - - - - - - g sqq TOTAL RAILROAD EXPENSE ------------------ |65700