Please note that UNLV may not own the copyright to these materials and cannot provide permission to publish or distribute materials when UNLV is not the copyright holder. The user is solely responsible for determining the copyright status of materials and obtaining permission to use material from the copyright holder and for determining whether any permissions relating to any other rights are necessary for the intended use, and for obtaining all required permissions beyond that allowed by fair use.
Read more about our reproduction and use policy.
I agree.Information
Digital ID
Permalink
Details
Member of
More Info
Rights
Digital Provenance
Publisher
Transcription
the locations shown by yellow lines on Exhibit "A", dated May 12, •*•954,^.attached hereto and by this reference incorporated herein, the following: a* Approximately 2,500 LF of 8" cast iron water mains* b* Approximately 3,130 LF of 6" cast iron water mains* c. Approximately 42 connections* LF of cast iron fire hydrant The cost of constructing said water mains (exclusive of constructing 42 LF of cast iron fire hydrant connections) is the agreed sum of f18,765*00* 2. Said water mains shall be constructed of 8" and 6" Class 150 B & S cast iron pipe and shall b^ in accordance with Federal Specifications WWP 421 Type 1* All joints shall be cement* All fittings shall be new, all bell cast iron e<|ual to ASA Standard Class 250* All valves shall be double disk, parallel seat bronze mountings conforming to AWWA Standards, not less than 175 lbs*, and all valve boxes shall be of cast iron of appropriate size for each valve* Unless otherwise approved by a duly authorized representative of the Company, all pipe valves and fittings shall be manufactured by the Pacific States Cast Iron Pipe Company or Mueller Company* All pipe lines shall be chlorinated in accordance with AWWA Specifications, shall be subject to the approval and acceptance of -State and City Health Authorities, and shall be constructed at an elevation to be designated by a duly authorized representative of the Company, but in no event shall there be less than 36" of covering over such water mains* All workmanship, material and installation of said water mains shall be subject to the