    This material is made available to facilitate private study, scholarship, or research. It may be protected by copyright, trademark, privacy, publicity rights, or other interests not owned by UNLV. Users are responsible for determining whether permissions are necessary from rights owners for any intended use and for obtaining all required permissions. Acknowledgement of the UNLV University Libraries is requested. For more information, please see the UNLV Special Collections policies on reproduction and use (https://www.library.unlv.edu/speccol/research_and_services/reproductions) or contact us at special.collections@unlv.edu.

    Digital Provenance

    Digitized materials: physical originals can be viewed in Special Collections and Archives reading room

    Publisher

    University of Nevada, Las Vegas. Libraries

    LA1SV EGAS1 215 d832A m h *s l a ^ // JT ORIG FS CY HHL JPM RE DISCUSSION AS TO SIZE PUMP WELL NO 4. JMA AND I AGREE WOULD BE INADVISABLE PLACE 9-7/8 INCH PUMP IN 10 INCH CASING EVEN IF REAMER RUN DOWN WELL* THE 1/16 INCH CLEARANCE BETWEEN SIDES OF PUMP BOWLS AND CASING WOULD RESULT IN BOWLS FREEZING TO SIDES OF CASING AND PREVENT REMOVAL OF PUMP* MY RECORDS SETP MEASUREMENTS INDICATED 310 GALS PER MIN* UNDERSTAND 9 INCH PUMP WOULD DELIVER 600 TO 650 GALS WHICH WOULD DOUBLE PRESENT OUTPUT THIS WELL. WE STRONGLY RECOMMEND AGAINST USE OF THE 9-7/8 INCH PUMP A318