Skip to main content

Search the Special Collections and Archives Portal

upr000043 221

Image

File
Download upr000043-221.tif (image/tiff; 23.68 MB)

Information

Digital ID

upr000043-221
    Details

    Rights

    This material is made available to facilitate private study, scholarship, or research. It may be protected by copyright, trademark, privacy, publicity rights, or other interests not owned by UNLV. Users are responsible for determining whether permissions are necessary from rights owners for any intended use and for obtaining all required permissions. Acknowledgement of the UNLV University Libraries is requested. For more information, please see the UNLV Special Collections policies on reproduction and use (https://www.library.unlv.edu/speccol/research_and_services/reproductions) or contact us at special.collections@unlv.edu.

    Digital Provenance

    Digitized materials: physical originals can be viewed in Special Collections and Archives reading room

    Publisher

    University of Nevada, Las Vegas. Libraries

    1 0 - feet in length, and plate scrap may not be less than h Inch in thickness* CAST STEEL, All cast steel not over 48 inches long or 18 inches wide not over ,05$ phosphorus or sulphur, free of alloys and attachments. May include heads, gates and risers, PUNCHINGS AND PLATE SCRAP. Punchings from plate and structural- steel scrap, not less than ?§? inch diameter, not over 0,05$ of phosphorus or sulphur, not over 0,5$ of silicon, free of alloys. Pieces must be cut 12 inches and under, TUBE SCRAP, Tube scrap, seamless or welded, not over 0,05$ phos­phorus and sulphur, free of alloys, Not more than 18 inches in length, and not over 6 inches inside diamenter. May be mashed or unmashed. Pieces over 6 indies inside diameter, may be included when thoroughly i/\ flattened. Must be new material. IV CUT STRUCTURAL AND PLATE SCRAP, 3 PEST AND UNDER. Clean, open-hearth steel plates, structural shapes, crop ends, shearings, or broken steel tires. Must be not less than i inch thick, cut to 3 feet and under. Not over 0.05$ of phosphorus or sulphur. CUT STRUCTURAL AND PLATE SCRAP, 2 FEET AND UNDER. Clean open-hearth steel plates, structural shapes, crop ends, shearings, or broken steel tires. Must be not less than i inch thick, cut to 2 feet and under. Not over 0.05$ of phosphorus or sulphur, CUT STRUCTURAL AND PLATE SCRAP, 1 FOOT AND UNDER. Clean open-hearth steel plates, structural shapes, crop ends, shearings, or broken steel tires. Must be not less than inch thick, cut to 1 foot and under. Not over 0,05$ of phosphorus or sulphur.