Please note that UNLV may not own the copyright to these materials and cannot provide permission to publish or distribute materials when UNLV is not the copyright holder. The user is solely responsible for determining the copyright status of materials and obtaining permission to use material from the copyright holder and for determining whether any permissions relating to any other rights are necessary for the intended use, and for obtaining all required permissions beyond that allowed by fair use.
Read more about our reproduction and use policy.
I agree.Information
Digital ID
Permalink
Details
Member of
More Info
Rights
Digital Provenance
Publisher
Transcription
V LAS VEGAS LAUD AND WATER COMPANY LAS VEGAS, NEVADA Water W ell No. 2 LAS VEGAS RANCH 1948 Depth T o tal o f Casing W ell in Deo.____________W ell HISTQBY 5 18 18 8 40 48 9 10 60 60 11 •75 62 12 100 98 13 135 126 14 147 144 15 162 160 16 174 166 19 20 175 166 21 - - 29 - - 30 mm 31 — — Jan. 1 177 166 2 230 166 3 235 166 5 - - 6 — - 7 Thawed le e out o f jack p ip e s Changed from w ater to o i l In jack tank Made new dump s t le k mount Welded brack ets on 20* p ip e so they would set on anchors I f p ip e moved. Put In 62 f t . o f 16n casin g Centered r i g over h o le, put on new c arb u reto rs, put on ja r s Water le v e l 8 AM 4 ' from lo g g in g point Water le v e l up to lo g g in g poin t W ell flo w in g approx. 10 GPM, 1200# p ressu re on gauge through lim estone o n ly. Then back to 0#. Casing i s s t i l l b e in g h e ld by f r i c t i o n b lo c k s, no p ressu re except through hard m a te ria l. That I s reason f o r no pressu re re ad in g . Flow approx. 10 GPM. P ip e does not go at 3000# on gauge, w i l l have to put In two more jac k s. (C asin g 166 f t . , up 3 f t . ) . Connected 4 ja c k s, made up drive-down sp ear, pushed 22000 on gauge and drove -at same time. P ip e s t i l l d id not go. Drove and pushed pipe 3 ". Broke drive-down spear at top o f m a n d rill. Made up f is h in g s t rin g , caught s o lid rod c o lla r at top o f m a n d rill and p u lle d out drive-down spear. Took socket o f f o f drive-down spear, b u i l t up adapter jo in t from 3 -4 -7 p in to s o lid rod th read, f i l l e d in around w e ll and made new top f o r s l i p h o ld e r. Put d riv e r in w e ll, drove and pushed at same tim e. Pipe d id not move. Reset main s i l l and made up d r i l l i n g t o o ls Hole cavin g, went to Burbank a f t e r under-reamer Took lo a d to Las Vegas; ran reamer 3 h rs . Ran reamer 4 h rs . T ried to push p ip e ; p u lle d anchors lo o s e ; l e t down r i g Moved r i g back and dug out anchors