Skip to main content

Search the Special Collections and Archives Portal

man000174 81

Image

File
Download man000174-081.tif (image/tiff; 25.79 MB)

Information

Digital ID

man000174-081
    Details

    Rights

    This material is made available to facilitate private study, scholarship, or research. It may be protected by copyright, trademark, privacy, publicity rights, or other interests not owned by UNLV. Users are responsible for determining whether permissions are necessary from rights owners for any intended use and for obtaining all required permissions. Acknowledgement of the UNLV University Libraries is requested. For more information, please see the UNLV Special Collections policies on reproduction and use (https://www.library.unlv.edu/speccol/research_and_services/reproductions) or contact us at special.collections@unlv.edu.

    Digital Provenance

    Digitized materials: physical originals can be viewed in Special Collections and Archives reading room

    Publisher

    University of Nevada, Las Vegas. Libraries

    ACCOUNTING REQUIREMENTS: At completion of the work the Contractor will furnish the Company a complete list of all quantities of material used in accordance with the Company*s classification in order to comply with Interstate Commerce Commission requirements. PERMITS; Contractor shall obtain and pay for all permits and licenses pertaining to his work and all work shall be done in strict accordance with any and all state and governmental laws and local ordinances governing same. In case of conflict be­tween the specifications or the plans and said laws and ordin­ances, the laws and ordinances shall govern. Certificate of inspection shall be turned over to the Engineer on completion of the work and before acceptance of the job. SECTION NO. 2 - SPECIFICATIONS; The^ Specifications hereinafter set forth shall cover the construction and installation of three transformer stations and connecting power lines. LOCATION; Transformer stations shall be located as shown on Dwg. J-202-1 dated May 11, 195U» marked Exhibit nB". TRANSFORMER PLATFORMS: Transformer platforms shall be constructed in accord­ance with details shown on Dwg. No. J-202-2, dated May 11, 1991|, marked Exhibit "C". Existing poles in power pole line may be used as one leg of platform if platform can be constructed immed lately adjacent to the power pole line. TRANSFORMERS: Transformers shall be of GE manufacture or equal, oil cooled, shipped with oil, and rated as follows; i*800 - 1*160 Y - primary, Sip08 - 1+80 - 21*0 secondary. Three single phase trans­formers shall be used at each installation. TRANSFORMER SCHEDULE: Well 11. 3 - 37-1/2 KVA transformers to furnish power for one 75 H.P. motor. 21*00 -3 -