Skip to main content

Search the Special Collections and Archives Portal

upr000192 245

Image

File
Download upr000192-245.tif (image/tiff; 26.72 MB)

Information

Digital ID

upr000192-245
    Details

    Rights

    This material is made available to facilitate private study, scholarship, or research. It may be protected by copyright, trademark, privacy, publicity rights, or other interests not owned by UNLV. Users are responsible for determining whether permissions are necessary from rights owners for any intended use and for obtaining all required permissions. Acknowledgement of the UNLV University Libraries is requested. For more information, please see the UNLV Special Collections policies on reproduction and use (https://www.library.unlv.edu/speccol/research_and_services/reproductions) or contact us at special.collections@unlv.edu.

    Digital Provenance

    Digitized materials: physical originals can be viewed in Special Collections and Archives reading room

    Publisher

    University of Nevada, Las Vegas. Libraries

    Las Vegas - October 27# 1953 Mr. C* K* Coryt v 23-1-89 oo « MHrr** VEf.ja . E«R eiBnehnanertdtt Will you please prepare the usual form of refund agreement with Federal Hones Development Company* Ino*, a Nevada corporation* whose address is Room 10* Cornet Building* Las Vegas* Nevada, covering construction of cast iron water mains and fire hydrant connections to serve Hyde Park Subdivision #3* Las Vegas, Nevada* as per map recorded in Book 3, Page 99 of Plats Clark County Nevada records* The location of said water mains and firs hydrant connections will be as indicated on attached Drawing J 193# dated October 1, 1953# eleven prints of which are attached hereto. SU9DIVIDSR A0REESJ 1* At its own expense to furnish all necessary labor and materials' and to construct* (a) Approximately 1330 LF ofI$w§8 oast iron water mains (b) Approximately 3475 LF of 8" cast iron water mains (e) Approximately 6810 LF of 6* cast iron water mains (d) Approximately 240 LF of 6* cast iron fire hydrant connections* The cost of constructing said water mains (exclusive of the cost of constructing fire hydrant connections) is the agreed sum of $70*100* 2. Said water mains shall be constructed of 12", 8* and 6* Class 150 Bell and Spigot cast iron pipe which shall conform with Federal specifications WWP 421 Type 1* All joints shall be cement* All fittings shall be new all bell oast iron equal to ASA Standard Glass 250* All valves shall be double disk# parallel seat# bronze mountings conforming to A W A standards, not less than 175 lbs*, and all valve boxes shall be of cast Iron of appropriate size for each valve* Unless otherwise approved by a duly authorized pspresentative of the Company, all pipe, valves and fittings shall be manu­factured by the Pacific States Cast Iron Pipe Company or Mueller Company* All pipe lines shall be chlorinated in accordance with AWWA specifications# shall be subject to acceptance and approval of the State and City Health Author!tlee* and shall be constructed at an elevation to be designated by duly authorized representative of the Company, but in no event shall there be less than 36® of cover over said water mains. All workmanship# material and installation of said water mains shall be subject to the approval and acceptance by duly authorized representa­tive of the Water Company*