Skip to main content

Search the Special Collections and Archives Portal

Report on total measurements of all water available in Las Vegas, 1934

File

File
Download hln000647.tif (image/tiff; 22.11 MB)

Information

Date

1934

Description

Report showing the decreased amount of water available from the Las Vegas Springs from 1931 to 1934. R-11 written in red at head of report.

Digital ID

hln000647

Physical Identifier

Box 15 Folder R11 Wells & Spring Railroad Company
Details

Citation

hln000647. Union Pacific Railroad Collection, 1828-1995. MS-00397. Special Collections and Archives, University Libraries, University of Nevada, Las Vegas. Las Vegas, Nevada. http://n2t.net/ark:/62930/d1mk6879c

Rights

This material is made available to facilitate private study, scholarship, or research. It may be protected by copyright, trademark, privacy, publicity rights, or other interests not owned by UNLV. Users are responsible for determining whether permissions are necessary from rights owners for any intended use and for obtaining all required permissions. Acknowledgement of the UNLV University Libraries is requested. For more information, please see the UNLV Special Collections policies on reproduction and use (https://www.library.unlv.edu/speccol/research_and_services/reproductions) or contact us at?special.collections@unlv.edu.

Standardized Rights Statement

Digital Provenance

Digitized materials: physical originals can be viewed in Special Collections and Archives reading room

Digital Processing Note

Manual transcription

Language

English

Format

application/pdf

TOTAL MEASUREMENTS OF ALL WATER AVAILABLE - LAS VEGAS July 1931 July 1934 Well 3.877,632 gals par day 2,507,040 gals per day Big Spring 1,040,496 " " " 954,852 " " Little Spring 913,043 " " " 823,680 " " Total available for Las Vegas 5,831,173 ' " " 4,285,572 " " " Middle Spring 440,659 " ' " 331,549 - " " Total 6,271,632 " " " 4,617,121 " July 1934 - 4,617,121 " Decrease 1,664,711 " " " or 26.4% decrease Estimated population - 7500 people Water available - 4,285,572 gals per day Per capita - 571.4 gals per day. MEASUREMENTS OF RESERVOIR AND SETTLING BASIN Reservoir Settling Basin Measurements during shortage, 9:30AM. July 17th, 1934...... 6 ft. 0 in. 1 ft. 6 in. After passing City Ordinance, 9:30AM, July 19, 1934........ Full Full Gain in reserve supply due to reduction in waste of water. ESTIMATED CONSUMPTION BY REFRIGERATOR SYSTEMS (which are the principal causes of wasted water) Sixty-four services use water-cooled refrigeration systems, without reclaiming the water for re-cooling. Cooling machine with piston displacement will consume: 4 1/2" piston displacement. 10 gal per min. 14,400 G.P.D. 432,000 GPMo. 2" " " 6 " " " 8,640 " 259,200 " Average 8 " " " 11,520 " 345,600 " Cost of water .0504 per 1000 gallons (Cost to LVL&WCo) 432,000 gals @ .0504 - $21.77 259,200 " .0505 - 13.06 Estimated loss of water through refrigeration systems: 64 services X 11,520 G.P.D. equals 737,280 gallons per day.