Skip to main content

Search the Special Collections and Archives Portal

upr000160 138

Image

File
Download upr000160-138.tif (image/tiff; 26.45 MB)

Information

Digital ID

upr000160-138
    Details

    Rights

    This material is made available to facilitate private study, scholarship, or research. It may be protected by copyright, trademark, privacy, publicity rights, or other interests not owned by UNLV. Users are responsible for determining whether permissions are necessary from rights owners for any intended use and for obtaining all required permissions. Acknowledgement of the UNLV University Libraries is requested. For more information, please see the UNLV Special Collections policies on reproduction and use (https://www.library.unlv.edu/speccol/research_and_services/reproductions) or contact us at special.collections@unlv.edu.

    Digital Provenance

    Digitized materials: physical originals can be viewed in Special Collections and Archives reading room

    Publisher

    University of Nevada, Las Vegas. Libraries

    e o p y Los Angeles, February 6, 1952 1-7334 Mr* Wm. Reinhardt: (GO - Mr* £. 0. Berwick Mr* R* L. Adamian) In connection with study of State permits for ap­propriation of water from wells at Las Vegas, Nevada, Mr. Ren-wiek baa raised the question as to whether the so-called "Shop Well", located in Railroad Company shop grounds near Round House, could be utilised to fill R. R. Co. requirements in event the Las Vegas Water District takes over the existing R* It. Co. transmission mains. The following data on Shop Well and flow through meters is submitted for consideration: (1) Shop Well requires a pump. Measurement on January 8, 1960, indicates a flow of 301 OPM, or 433,400 OPD when pumping into top of water softener with 25# pressure at pump, or 65# pressure at pump when pumping against a closed valve. This flow would, no doubt, dacrease substantially with continued use since this well had not been used for several months prior to above measurement. (2) Shop Well constructed 1920-21. Casing - 0* - 236* is 12* iron Double X 236* - 700* * 10* * * * Perforations - 6 per 10* - 280’ to 290’ 6 " 10* - 5901 * 594* Ho filing made with State Engineer. (3) Flow through meters serving R. R. Co. facilities and industries in 1951 was, as follows: Year 1951 Month of July 1961 Total Av- Total Average for Year erage in July- Gals. Name of Meter Gallons C.F.S. Gallons Psr Day Stock Yds.(Old) 1,836,700 230,000 Power House 13,239,300 2,501,900 •Coach Hydrant 7 617,900 810,400 Tank Cars 4,259,700 461,800 *R.R. Rooming House 2,549,200 390,130 Water Softener H II 2,250,800) 052 9,919,700 697,800 •Hew Stock Yds. 92.100 11.400 Total R.R. Meters 41,765,400 0.177 5,103,430 170,110 •P.F.E. Meter 21,628,840 0.092 2,717,710 90,590 •Other Industries 8.210.190 0.035 936.930 31.380 71,604,430 0.304 8,758,070 291,930