Skip to main content

Search the Special Collections and Archives Portal

man000174 110

Image

File
Download man000174-110.tif (image/tiff; 26.98 MB)

Information

Digital ID

man000174-110
    Details

    Rights

    This material is made available to facilitate private study, scholarship, or research. It may be protected by copyright, trademark, privacy, publicity rights, or other interests not owned by UNLV. Users are responsible for determining whether permissions are necessary from rights owners for any intended use and for obtaining all required permissions. Acknowledgement of the UNLV University Libraries is requested. For more information, please see the UNLV Special Collections policies on reproduction and use (https://www.library.unlv.edu/speccol/research_and_services/reproductions) or contact us at special.collections@unlv.edu.

    Digital Provenance

    Digitized materials: physical originals can be viewed in Special Collections and Archives reading room

    Publisher

    University of Nevada, Las Vegas. Libraries

    V J A M E S M. M O N T G O M E R Y • C O N S U L T I N G E N G I N E E R • 15 N O R T H O A K L A N D A V E N U E • P A S A D E N A 1, C A L I F O R N I A Mr. Campbell Las Vegas Valley Water Dist. -3- 4-13-54 a zoning variance, a pressure sand trap, the encroachment upon potential subdivision area, and the necessity for quick action. After considering these various factors it was thought best to locate the wells on Water Company land where sand traps are already available and no zoning va ri­ance would be required. It is believed that both proposed wells will be capable of delivering 2500 gpm. Well No. 12 is so located that it will probably result in a de­crease in production from Wells Nos. 8, 9 and 10 (based on their existing pump curves) of about 400 gpm, leaving a net gain of 2100 gpm. The be­havior of Well No. 13 is more difficult to predict, but it is believed that the net gain will be in the neighborhood of about 1800-2000 gpm. Such added capacity should be sufficient to carry the City over peak demand periods this coming summer. In conjunction with drilling these wells, it w ill be necessary to file applications for permits to appropriate and to put to beneficial use the water needed. Section 6 of Chapter 178, An Act Relating to Under­ground Waters, requires that said permits be obtained prior to the con­struction of the wells to be used for the appropriation. The length of time involved in processing these permits would probably be about 10 weeks and the drilling of these wells after such a period of time would mean that they would not be available for this summer's use. As a r e ­sult, the District should probably intercede for the Land and Water Company with the State Engineer, and as a public necessity, ask for special permission to drill the wells concurrently with the processing of the permits. There is a number of engineering details on these proposed in­stallations that are beyond the scope of this letter. I will be available to the Land and Water Company to discuss the project and assist in any way I can. In order that the Land and Water Company officials may know more quickly of the recommendations being made, copies of this letter are being sent to Mr. Bennett and Mr. Maag. A copy is also being mailed to Mr. Shamberger. JMM:mg cc: Mr. Bennett cc: Mr. Maag cc: Mr. Hugh Shamberger